Analytical validation of hemolysis detection on GEM Premier 7000Laura Pighion May 26, 2025 at 10:00 am
Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0525. Online ahead of print. NO ABSTRACT PMID:40418775 | DOI:10.1515/cclm-2025-0525

Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0525. Online ahead of print. NO ABSTRACT PMID:40418775 | DOI:10.1515/cclm-2025-0525
Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0311. Online ahead of print. ABSTRACT OBJECTIVES: To describe the structure of vitamin D metabolome and investigate the possible cause of high serum levels of C3 epimers of 25-(OH)D in preterm infants, we compared the vitamin D metabolites in umbilical cord blood with serum samples taken at … Read more
Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0448. Online ahead of print. ABSTRACT OBJECTIVES: Quality indicator (QI) monitoring is essential to quality assurance for point of care testing (POCT). QI standardization is needed in the POCT field to provide clear guidance to hospitals and produce National and International benchmarks. A central aim was to … Read more
Clin Chem Lab Med. 2025 May 8. doi: 10.1515/cclm-2025-0531. Online ahead of print. NO ABSTRACT PMID:40418679 | DOI:10.1515/cclm-2025-0531
Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0550. Online ahead of print. NO ABSTRACT PMID:40418841 | DOI:10.1515/cclm-2025-0550
Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0409. Online ahead of print. ABSTRACT OBJECTIVES: Antigen excess (AE) or high dose hook-effect can seriously affect the reported concentration of an analyte, which may impact clinical decisions. This study analyze to what extent the Roche Elecsys® Myoglobin assay is affected by antigen excess and how this … Read more
Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0319. Online ahead of print. ABSTRACT OBJECTIVES: Coagulation test results may be affected by hemolysis, icterus and/or lipemia (HIL). Detailed guidelines for HIL-management are missing, both for manual and automatic HIL-checks. The aim of this survey was to provide an overview of the practical procedures for the … Read more
Clin Chem Lab Med. 2025 May 22. doi: 10.1515/cclm-2025-0210. Online ahead of print. ABSTRACT OBJECTIVES: The aim of this study was to carry out a cross-analysis of the morphological abnormalities (MA) and the electrophoretic profile (EP) of blood samples suspect for heterozygous haemoglobinopathies (HTZ HGP). Screening for HTZ HGP was based on erythrocyte parameters provided … Read more
Clin Chem Lab Med. 2025 May 5. doi: 10.1515/cclm-2025-0418. Online ahead of print. ABSTRACT Cardiac injury, encompassing a spectrum of heart muscle damage, requires prompt and accurate diagnosis to improve patient outcomes. Early detection using cardiac biomarkers is vital for timely intervention and reducing mortality. This review highlights the role of high-sensitivity cardiac troponins (hs-cTns) … Read more
Clin Chem Lab Med. 2025 May 5. doi: 10.1515/cclm-2025-0490. Online ahead of print. ABSTRACT After the dissemination of a manifesto for the implementation of value-based laboratory medicine (VBLM) and a Strategic Conference dedicated to this issue, a novel initiative of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) is to be initiated with … Read more